Specifications: | |
Model Number | DA-ART-ARC3000H-03-FW2-868 |
Input and Output | |
Wireless Protection Zone | Hub: 150-channel wireless peripherals (6 sirens, 64 wireless keyfobs) |
Port | |
Buzzer | Hub: Built-in |
Button | Hub: 1 × reset, 1 × power, 1 × AP Keyfob: 4 (Home, Away, Disarm, and SOS) Door Detector: 1 × power button PIR Detector: 1 × power button |
Indicator Light | Hub: 1 for multiple statuses (alarm, arming, disarming, networking, and malfunction) Keyfob: 1 × two-color status indicator (green: normal, red: abnormal) Door Detector: 1 × green alarm indicator PIR Detector: 1 × green alarm indicator |
Storage Battery | Hub: Built-in lithium battery |
Network Mode | Single SIM (GSM:900/1800 MHz, WCDMA:B1/B5/B8, LTE-FDD:B1/B3/B5/B7/B8/B20, LTE-TDD:B38/B40/B41); dual SIM single standby |
Network Port | Hub: 1 × RJ-45 10 M/100 M Ethernet port |
Function | |
Nework Protocol | Hub: TCP/IP, including PPTP, L2TP, DHCP, UPNP, and NTP |
Offline Cache | Hub: Max. 50 entries (ANR) |
Power Failure Protection for Configured Parameters | Hub: Yes |
Remote Update | All; Cloud Update |
Video Linkage | Hub: Yes |
SMS | Hub: Yes (up to 5 phone numbers) |
Phone Call | Hub: Yes (up to 5 phone numbers) |
Low Battery Alarm | All: Yes |
Tamper Alarm | Hub: Yes Door Detector: Yes PIR Detector: Yes |
User Management | Hub: Share function for App users |
Search | Hub: Searching push messages, device status, and program version. Detecting signal strength. Keyfob: Signal strength detection Door Detector: Signal strength detection PIR Detector: Signal strength detection |
Arm and Disarm | Hub: App; keyfob; schedule |
Wireless | |
Carrier Frequency | All: 868.0 MHz–868.6 MHz |
Communication Distance | Hub: Up to 2,000 m (6,561.68 ft) in an open space Keyfob: Up to 900 m (2,952.76 ft) in an open space Door Detector: Up to 1,200 m (3,937.01 ft) in an open space PIR Detector: Up to 1,600 m (5,249.34 ft) in an open space |
Communication Mechanism | All: Two-way |
Frequency Hopping | All: Yes |
Encryption Mode | All: AES128 |
Wifi | Hub: 2.4G |
Peripherals | |
External Zone | Door Detection: 1-channel dry contact input |
Temperature | |
Measuring Range (Temperature) | Door Detector: –15 °C to +65 °C (+18.8 °F to +149 °F) (indoor) PIR Detector: –15 °C to +65 °C (+18.8 °F to +149 °F) (indoor) |
Measuring Precision (Temperature) | Door Detector: ± 1 °C (± 33.8 °F) PIR Detector: ± 1 °C (± 33.8 °F) |
Resolution (Temperature) | Door Detector: 1 °C (33.8 °F) PIR Detector: 1 °C (33.8 °F) |
Specification | |
Sensor | Door Detector: Reed switch PIR Detector: Dual elements low-noise PIR sensor |
Test Mode | Door Detector: Yes PIR Detector: Yes |
Scenario | Door Detector: Non-metal doors |
Movement Distance | Door Detector: < 40 mm (1.57") |
Detection Mode | PIR Detector: PIR |
Detection Range | PIR Detector: 12 m (39.37 ft) (90°) with installtion height of 2.2 m (7.21 ft) |
Detection Speed | PIR Detector: 0.3 m/s–3 m/s (0.98 ft/s–9.84 ft/s) |
Pet Immunity Level | PIR Detector: ≤ 18 kg (39.68 lb) |
White Light Resistance Level | PIR Detector: 6500 lx |
Two-way Digital Temperature Compensation | PIR Detector: Yes, no attenuation of detection distance in high temperature |
Sensitivity | PIR Detector: 3 levels adjustable |
General | |
Power Supply | Hub: 12 V DC, 1.5 A (Europe, UK and USA power adapters are optional) Keyfob: CR2032 battery Door Detector: CR123A battery PIR Detector: CR123A battery |
Battery Life | Hub: Storage battery standby for 12 Hours Keyfob: 5 years Door Detector: 5 years PIR Detector: 4 years |
Power Consumption | Keyfob: Max. 100 mW Door Detector: Max. 125 mW PIR Detector: Max. 120 mW |
Operating Temperature | Hub: –10 °C to +50 °C (+14 °F to +122 °F) (indoor) Keyfob: –10 °C to +55 °C (+14 °F to +131 °F) (indoor) Door Detector: –10 °C to +55 °C (+14 °F to +131 °F) (indoor) PIR Detector: –10 °C to +55 °C (+14 °F to +131 °F) (indoor) |
Operating Humidity | All: 10%–90% (RH) |
Product Dimensions | Hub: 163.0 mm × 163.0 mm × 32.0 mm (6.42"" × 6.42"" × 1.26"") (L × W × H) Keyfob: 60.0 mm × 39.5 mm × 15.0 mm (2.36"" × 1.56"" × 0.59"") (L × W × H) Door Detector: 100.2 mm × 20.8 mm × 20.3 mm (3.94"" × 0.82"" × 0.80"") (L × W × H) PIR Detector: 104.0 mm × 60.0 mm × 50.0 mm (4.09"" × 2.36"" × 1.97"") (L × W × H) |
Packaging Dimensions | Hub: 219.0 mm × 187.0 mm × 91.0 mm (8.62"" × 7.36"" × 3.58"") (L × W × H) Keyfob: 135.0 mm × 98.5 mm × 27.8 mm (5.31"" × 3.88"" × 1.09"") (L × W × H) Door Detector: 135.0 mm × 98.5 mm × 27.8 mm (5.31"" × 3.88"" × 1.09"") (L × W × H) PIR Detector: 135.0 mm × 98.5 mm × 56.8 mm (5.31"" × 3.88"" × 2.24"") (L × W × H) |
Installation | Hub: Wall mount; Desktop Door Detector: Bracket mount PIR Detector: Wall mount |
Net Weight | Hub: 0.38 Kg (0.84 lb) Keyfob: 20 g (0.04 lb) Door Detector: 70 g (0.15 lb) PIR Detector: 100 g (0.22 lb) |
Gross Weight | Hub: 0.8 Kg (1.76 lb) Keyfob: 65 g (0.14 lb) Door Detector: 115 g (0.25 lb) PIR Detector: 170 g (0.37 lb) |
Certifications | All: CE |
Casing | All: PC + ABS |